9,49 €
Comparison of Mixed H 2 H8 with Regional Pole Placement Control and H 2 Optimal Control for the Design of Steam Condenser
Comparison of Mixed H 2 H8 with Regional Pole Placement Control and H 2 Optimal Control for the Design of Steam Condenser
  • Sold out
Comparison of Mixed H 2 H8 with Regional Pole Placement Control and H 2 Optimal Control for the Design of Steam Condenser
Comparison of Mixed H 2 H8 with Regional Pole Placement Control and H 2 Optimal Control for the Design of Steam Condenser
El. knyga:
9,49 €
Research Paper (undergraduate) from the year 2020 in the subject Electrotechnology, , language: English, abstract: This paper investigates the comparison between mixed H 2 /H8 with regional pole placement control and H 2 optimal control for the design of steam condenser. The comparison have been made for a step change in the steam condenser pressure set point for a step change of 10 & 23 seconds using MATLAB/Simulink environment for the steam condenser with mixed H 2 /H8 with regional pole…
  • Publisher:
  • Year: 2020
  • Pages: 8
  • ISBN: 9783346161659
  • ISBN-10: 334616165X
  • ISBN-13: 9783346161659
  • Format: PDF
  • Language: English

Comparison of Mixed H 2 H8 with Regional Pole Placement Control and H 2 Optimal Control for the Design of Steam Condenser (e-book) (used book) | bookbook.eu

Reviews

Description

Research Paper (undergraduate) from the year 2020 in the subject Electrotechnology, , language: English, abstract: This paper investigates the comparison between mixed H 2 /H8 with regional pole placement control and H 2 optimal control for the design of steam condenser. The comparison have been made for a step change in the steam condenser pressure set point for a step change of 10 & 23 seconds using MATLAB/Simulink environment for the steam condenser with mixed H 2 /H8 with regional pole placement controller, steam condenser with H 2 optimal controller and steam condenser without controller. The steam condenser with mixed H 2 /H8 with regional pole placement controller presented excellent and superior dynamic performance in response to the two step changes and an improvement in settling time. The overall simulation results demonstrated that the steam condenser with mixed H 2 /H8 with regional pole placement controller can be an efficient alternative to the steam condenser with H 2 optimal controller for the steam condenser.

9,49 €
Log in and for this item
you will receive
0,09 Book Euros! ?

Electronic book:
Delivery after ordering is instant! Intended for reading only on a computer, tablet or other electronic device.

Lowest price in 30 days: 9,49 €

Lowest price recorded: Price has not changed

  • Author: Mustefa Jibril
  • Publisher:
  • Year: 2020
  • Pages: 8
  • ISBN: 9783346161659
  • ISBN-10: 334616165X
  • ISBN-13: 9783346161659
  • Format: PDF
  • Language: English English

Research Paper (undergraduate) from the year 2020 in the subject Electrotechnology, , language: English, abstract: This paper investigates the comparison between mixed H 2 /H8 with regional pole placement control and H 2 optimal control for the design of steam condenser. The comparison have been made for a step change in the steam condenser pressure set point for a step change of 10 & 23 seconds using MATLAB/Simulink environment for the steam condenser with mixed H 2 /H8 with regional pole placement controller, steam condenser with H 2 optimal controller and steam condenser without controller. The steam condenser with mixed H 2 /H8 with regional pole placement controller presented excellent and superior dynamic performance in response to the two step changes and an improvement in settling time. The overall simulation results demonstrated that the steam condenser with mixed H 2 /H8 with regional pole placement controller can be an efficient alternative to the steam condenser with H 2 optimal controller for the steam condenser.

Reviews

  • No reviews
0 customers have rated this item.
5
0%
4
0%
3
0%
2
0%
1
0%
(will not be displayed)