128,06 €
142,29 €
-10% with code: EXTRA
Method development and validation by Gas chromatography-HeadSpace
Method development and validation by Gas chromatography-HeadSpace
128,06
142,29 €
  • We will send in 10–14 business days.
Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, ethanol, acetone and toluene) in Omeprazole API was investigated.The Head space gas chromatography (HSGC) method described in this investigation utilized a DB - 624, 30 m long x 0.32 mm internal…
  • SAVE -10% with code: EXTRA

Method development and validation by Gas chromatography-HeadSpace (e-book) (used book) | bookbook.eu

Reviews

Description

Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, ethanol, acetone and toluene) in Omeprazole API was investigated.The Head space gas chromatography (HSGC) method described in this investigation utilized a DB - 624, 30 m long x 0.32 mm internal diameter, 1.8 μm thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 180°C to prevent degradation. The initial oven temperature was set at 50°C for 10 min and programmed at a rate of 30°C min-1 to a final temperature of 200°C for 10 min. Nitrogen was used as a carrier gas and flame ionization detector was used. N, N-dimethyl formamide was selected as a diluent. The method was validated according to ICH guidelines and found to be specific, linear i.e., C.C is 0.998, % RSD of each analyte is less than 8%, sensitive, rugged and showed excellent recovery.

EXTRA 10 % discount with code: EXTRA

128,06
142,29 €
We will send in 10–14 business days.

The promotion ends in 21d.05:29:45

The discount code is valid when purchasing from 10 €. Discounts do not stack.

Log in and for this item
you will receive 1,42 Book Euros!?

Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, ethanol, acetone and toluene) in Omeprazole API was investigated.The Head space gas chromatography (HSGC) method described in this investigation utilized a DB - 624, 30 m long x 0.32 mm internal diameter, 1.8 μm thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 180°C to prevent degradation. The initial oven temperature was set at 50°C for 10 min and programmed at a rate of 30°C min-1 to a final temperature of 200°C for 10 min. Nitrogen was used as a carrier gas and flame ionization detector was used. N, N-dimethyl formamide was selected as a diluent. The method was validated according to ICH guidelines and found to be specific, linear i.e., C.C is 0.998, % RSD of each analyte is less than 8%, sensitive, rugged and showed excellent recovery.

Reviews

  • No reviews
0 customers have rated this item.
5
0%
4
0%
3
0%
2
0%
1
0%
(will not be displayed)