130,22 €
144,69 €
-10% with code: EXTRA
Graphitized Carbon Foam With Phase Change Material
Graphitized Carbon Foam With Phase Change Material
130,22
144,69 €
  • We will send in 10–14 business days.
The transient heating and cooling responses of graphitized carbon foam infiltrated with phase change material (PCM) are studied, including thermal cycling, analytical modeling, contact resistance, and the temperature gradient through the infiltrated foam. Infiltrating carbon foam with PCM creates an effective thermal energy storage device (TESD). The high thermal conductivity of the graphite ligaments in the foam allows rapid transfer of heat throughout the PCM volume. The PCM, chosen for its h…
144.69
  • SAVE -10% with code: EXTRA

Graphitized Carbon Foam With Phase Change Material (e-book) (used book) | bookbook.eu

Reviews

Description

The transient heating and cooling responses of graphitized carbon foam infiltrated with phase change material (PCM) are studied, including thermal cycling, analytical modeling, contact resistance, and the temperature gradient through the infiltrated foam. Infiltrating carbon foam with PCM creates an effective thermal energy storage device (TESD). The high thermal conductivity of the graphite ligaments in the foam allows rapid transfer of heat throughout the PCM volume. The PCM, chosen for its high heat capacity and high heat of fusion, stores the heat for later removal. The PCM is able to absorb a significant amount of heat without a significant increase in temperature during phase change. Three different types of carbon foam were selected for this study, and a fully-refined paraffin wax was chosen for the PCM. Experimental samples of foam and PCM were heated on a temperature-controlled heater block from room temperature through phase change and to steady-state. Heat was then removed using a liquid-cooled cooling block. A data acquisition unit recorded temperatures throughout the experimental sample, the heater, and cooler every four seconds. The heating and cooling responses were modeled using an exponential function. The results show a decrease in the temperature rate of change during melting and solidifying of the PCM. Multiple cycles of heating and cooling the sample produced consistent responses.

EXTRA 10 % discount with code: EXTRA

130,22
144,69 €
We will send in 10–14 business days.

The promotion ends in 21d.19:22:12

The discount code is valid when purchasing from 10 €. Discounts do not stack.

Log in and for this item
you will receive 1,45 Book Euros!?
  • Author: Angelinda D Fedden
  • Publisher:
  • ISBN-10: 1249594014
  • ISBN-13: 9781249594017
  • Format: 18.9 x 24.6 x 0.3 cm, minkšti viršeliai
  • Language: English English

The transient heating and cooling responses of graphitized carbon foam infiltrated with phase change material (PCM) are studied, including thermal cycling, analytical modeling, contact resistance, and the temperature gradient through the infiltrated foam. Infiltrating carbon foam with PCM creates an effective thermal energy storage device (TESD). The high thermal conductivity of the graphite ligaments in the foam allows rapid transfer of heat throughout the PCM volume. The PCM, chosen for its high heat capacity and high heat of fusion, stores the heat for later removal. The PCM is able to absorb a significant amount of heat without a significant increase in temperature during phase change. Three different types of carbon foam were selected for this study, and a fully-refined paraffin wax was chosen for the PCM. Experimental samples of foam and PCM were heated on a temperature-controlled heater block from room temperature through phase change and to steady-state. Heat was then removed using a liquid-cooled cooling block. A data acquisition unit recorded temperatures throughout the experimental sample, the heater, and cooler every four seconds. The heating and cooling responses were modeled using an exponential function. The results show a decrease in the temperature rate of change during melting and solidifying of the PCM. Multiple cycles of heating and cooling the sample produced consistent responses.

Reviews

  • No reviews
0 customers have rated this item.
5
0%
4
0%
3
0%
2
0%
1
0%
(will not be displayed)