65,15 €
72,39 €
-10% with code: EXTRA
Force Decay Evaluation of Thermoplastic & Thermoset Elastomeric Chains
Force Decay Evaluation of Thermoplastic & Thermoset Elastomeric Chains
65,15
72,39 €
  • We will send in 10–14 business days.
Orthodontic power chains are replaced at 3 to 4 week intervals due to force decay. Studies on power chains often do not differentiate between thermoplastic (TP) and thermoset (TS) elastomers and, to date, no study has compared between them. We sought to compare over a period of 8 weeks: (1) force decay between TP and TS power chains, (2) force decay between using two different initial forces, (3) force decay between direct chains and chain loops. Our results showed 20% more force decay in the T…
  • SAVE -10% with code: EXTRA

Force Decay Evaluation of Thermoplastic & Thermoset Elastomeric Chains (e-book) (used book) | bookbook.eu

Reviews

Description

Orthodontic power chains are replaced at 3 to 4 week intervals due to force decay. Studies on power chains often do not differentiate between thermoplastic (TP) and thermoset (TS) elastomers and, to date, no study has compared between them. We sought to compare over a period of 8 weeks: (1) force decay between TP and TS power chains, (2) force decay between using two different initial forces, (3) force decay between direct chains and chain loops. Our results showed 20% more force decay in the TP power chains compared to the TS ones. Direct chains had more force decay compared to chain loops only in the OrTP power chains. There was no significant difference in force decay between using light and heavy forces. In conclusion, contrary to the interchangeable use of TP and TS power chains in published literature and in clinical practice, this study demonstrates that they perform differently under stress and that a clear distinction should be made.

EXTRA 10 % discount with code: EXTRA

65,15
72,39 €
We will send in 10–14 business days.

The promotion ends in 20d.04:50:09

The discount code is valid when purchasing from 10 €. Discounts do not stack.

Log in and for this item
you will receive 0,72 Book Euros!?

Orthodontic power chains are replaced at 3 to 4 week intervals due to force decay. Studies on power chains often do not differentiate between thermoplastic (TP) and thermoset (TS) elastomers and, to date, no study has compared between them. We sought to compare over a period of 8 weeks: (1) force decay between TP and TS power chains, (2) force decay between using two different initial forces, (3) force decay between direct chains and chain loops. Our results showed 20% more force decay in the TP power chains compared to the TS ones. Direct chains had more force decay compared to chain loops only in the OrTP power chains. There was no significant difference in force decay between using light and heavy forces. In conclusion, contrary to the interchangeable use of TP and TS power chains in published literature and in clinical practice, this study demonstrates that they perform differently under stress and that a clear distinction should be made.

Reviews

  • No reviews
0 customers have rated this item.
5
0%
4
0%
3
0%
2
0%
1
0%
(will not be displayed)