28,97 €
32,19 €
-10% with code: EXTRA
Fire Resistance of Structural Composite Lumber Products
Fire Resistance of Structural Composite Lumber Products
28,97
32,19 €
  • We will send in 10–14 business days.
Use of structural composite lumber products is increasing. In applications requiring a fire resistance rating, calculation procedures are used to obtain the fire resistance rating of exposed structural wood products. A critical factor in the calculation procedures is char rate for ASTM E 119 fire exposure. In this study, we tested 14 structural composite lumber products to determine char rate when subjected to the fire exposure of the standard fire resistance test. Char rate tests on 10 of the…
  • SAVE -10% with code: EXTRA

Fire Resistance of Structural Composite Lumber Products (e-book) (used book) | bookbook.eu

Reviews

(5.00 Goodreads rating)

Description

Use of structural composite lumber products is increasing. In applications requiring a fire resistance rating, calculation procedures are used to obtain the fire resistance rating of exposed structural wood products. A critical factor in the calculation procedures is char rate for ASTM E 119 fire exposure. In this study, we tested 14 structural composite lumber products to determine char rate when subjected to the fire exposure of the standard fire resistance test. Char rate tests on 10 of the composite lumber products were also conducted in an intermediate-scale horizontal furnace. The National Design Specification/Technical Report 10 design procedure for calculating fire resistance ratings of exposed wood members can be used to predict failure times for members loaded in tension. Thirteen tests were conducted in which composite lumber products were loaded in tension as they were subjected to the standard fire exposure of ASTM E 119. Charring rates, observed failure times in tension tests, and deviations from predicted failure times of the structural composite lumber products were within expected range of results for sawn lumber and glued laminated timbers.

EXTRA 10 % discount with code: EXTRA

28,97
32,19 €
We will send in 10–14 business days.

The promotion ends in 18d.03:09:49

The discount code is valid when purchasing from 10 €. Discounts do not stack.

Log in and for this item
you will receive 0,32 Book Euros!?

Use of structural composite lumber products is increasing. In applications requiring a fire resistance rating, calculation procedures are used to obtain the fire resistance rating of exposed structural wood products. A critical factor in the calculation procedures is char rate for ASTM E 119 fire exposure. In this study, we tested 14 structural composite lumber products to determine char rate when subjected to the fire exposure of the standard fire resistance test. Char rate tests on 10 of the composite lumber products were also conducted in an intermediate-scale horizontal furnace. The National Design Specification/Technical Report 10 design procedure for calculating fire resistance ratings of exposed wood members can be used to predict failure times for members loaded in tension. Thirteen tests were conducted in which composite lumber products were loaded in tension as they were subjected to the standard fire exposure of ASTM E 119. Charring rates, observed failure times in tension tests, and deviations from predicted failure times of the structural composite lumber products were within expected range of results for sawn lumber and glued laminated timbers.

Reviews

  • No reviews
0 customers have rated this item.
5
0%
4
0%
3
0%
2
0%
1
0%
(will not be displayed)