78,20 €
86,89 €
-10% with code: EXTRA
Design of Hydraulic Steel Structures
Design of Hydraulic Steel Structures
78,20
86,89 €
  • We will send in 10–14 business days.
This manual prescribes guidance for designing hydraulic steel structures (HSS) by load and resistance factor design (LRFD) and guidance for fracture control. Allowable stress design (ASD) guidance is provided as an alternative design procedure or for those structure types where LRFD criteria have yet to be developed. Typical HSS are lock gates, tainter gates, tainter valves, bulkheads and stoplogs, vertical lift gates, components of hydroelectric and pumping plants, and miscellaneous structures…
  • SAVE -10% with code: EXTRA

Design of Hydraulic Steel Structures (e-book) (used book) | bookbook.eu

Reviews

(5.00 Goodreads rating)

Description

This manual prescribes guidance for designing hydraulic steel structures (HSS) by load and resistance factor design (LRFD) and guidance for fracture control. Allowable stress design (ASD) guidance is provided as an alternative design procedure or for those structure types where LRFD criteria have yet to be developed. Typical HSS are lock gates, tainter gates, tainter valves, bulkheads and stoplogs, vertical lift gates, components of hydroelectric and pumping plants, and miscellaneous structures such as lock wall accessories, local flood protection gates, and outlet works gates. HSS may be subject to submergence, wave action, hydraulic hammer, cavitation, impact, corrosion, and severe climatic conditions.

EXTRA 10 % discount with code: EXTRA

78,20
86,89 €
We will send in 10–14 business days.

The promotion ends in 20d.12:57:58

The discount code is valid when purchasing from 10 €. Discounts do not stack.

Log in and for this item
you will receive 0,87 Book Euros!?

This manual prescribes guidance for designing hydraulic steel structures (HSS) by load and resistance factor design (LRFD) and guidance for fracture control. Allowable stress design (ASD) guidance is provided as an alternative design procedure or for those structure types where LRFD criteria have yet to be developed. Typical HSS are lock gates, tainter gates, tainter valves, bulkheads and stoplogs, vertical lift gates, components of hydroelectric and pumping plants, and miscellaneous structures such as lock wall accessories, local flood protection gates, and outlet works gates. HSS may be subject to submergence, wave action, hydraulic hammer, cavitation, impact, corrosion, and severe climatic conditions.

Reviews

  • No reviews
0 customers have rated this item.