109,61 €
121,79 €
-10% with code: EXTRA
Adaptive Wavefront Correction in Two-photon Microscopy - Coherence-Gated Wavefront Sensing
Adaptive Wavefront Correction in Two-photon Microscopy - Coherence-Gated Wavefront Sensing
109,61
121,79 €
  • We will send in 10–14 business days.
The focus of a two-photon microscope is often degraded by inhomogeneities in the refractive index within biological specimens. In this book it is shown for various specimens, even for living zebrafish, that the resolution and the fluorescence signal of a two-photon microscope can be substantially improved by using adaptive optics, i.e. wavefront correction based on coherence-gated wavefront sensing (CGWS). The advantage of using CGWS relies on the fact that the wavefront distortions are sensed…
  • SAVE -10% with code: EXTRA

Adaptive Wavefront Correction in Two-photon Microscopy - Coherence-Gated Wavefront Sensing (e-book) (used book) | bookbook.eu

Reviews

Description

The focus of a two-photon microscope is often degraded by inhomogeneities in the refractive index within biological specimens. In this book it is shown for various specimens, even for living zebrafish, that the resolution and the fluorescence signal of a two-photon microscope can be substantially improved by using adaptive optics, i.e. wavefront correction based on coherence-gated wavefront sensing (CGWS). The advantage of using CGWS relies on the fact that the wavefront distortions are sensed by backscattered instead of fluorescent light. Thus, neither photodamage nor photobleaching occurs and wavefront distortions can be sensed in less than 1 microsecond with an accuracy of lambda/50, even in strongly scattering samples. Furthermore, CGWS is thoroughly investigated for all relevant parameters affecting the measurement process, such as coherence length, polarization of the light, density of scatterers, and coherence-gate position. The book is mainly addressed to experts in the field of optical physics and light microscopy.

EXTRA 10 % discount with code: EXTRA

109,61
121,79 €
We will send in 10–14 business days.

The promotion ends in 19d.17:33:32

The discount code is valid when purchasing from 10 €. Discounts do not stack.

Log in and for this item
you will receive 1,22 Book Euros!?

The focus of a two-photon microscope is often degraded by inhomogeneities in the refractive index within biological specimens. In this book it is shown for various specimens, even for living zebrafish, that the resolution and the fluorescence signal of a two-photon microscope can be substantially improved by using adaptive optics, i.e. wavefront correction based on coherence-gated wavefront sensing (CGWS). The advantage of using CGWS relies on the fact that the wavefront distortions are sensed by backscattered instead of fluorescent light. Thus, neither photodamage nor photobleaching occurs and wavefront distortions can be sensed in less than 1 microsecond with an accuracy of lambda/50, even in strongly scattering samples. Furthermore, CGWS is thoroughly investigated for all relevant parameters affecting the measurement process, such as coherence length, polarization of the light, density of scatterers, and coherence-gate position. The book is mainly addressed to experts in the field of optical physics and light microscopy.

Reviews

  • No reviews
0 customers have rated this item.
5
0%
4
0%
3
0%
2
0%
1
0%
(will not be displayed)